SKU: B04
Category: Medium Voltage Cable Accessories
24 & 36 kV for single core joint with mechanical connector
Descriptions
Specifications
MV joint with mechanical connector (MXSU)
Inline joint for 1-core polymeric cables with copper wire shield, without armour
Kit Number | 12kV | 24kV | 36kV | Diameter | Diameter over | Diameter Cable | Price | |||||
Conductor | Core Insulation | Oversheath | Baht/1core kit | |||||||||
MXSU | – | 3111 | 25-95 | 5.2 – 12.0 | mm. | 13.2 – 21.8 | mm. | 23 – 32 | mm. | สอบถาม | ||
MXSU | – | 3121 | 70-150 | 8.7 – 15.0 | mm. | 17.6 – 24.3 | mm. | 25 – 38 | mm. | สอบถาม | ||
MXSU | – | 3131 | 95-240 | 10.3 – 19.2 | mm. | 17.6 -29.4 | mm. | 26 – 40 | mm. | สอบถาม | ||
MXSU | – | 3132 | 150-300 | 12.9 – 21.6 | mm. | 21.6 -30.4 | mm. | 29 – 43 | mm. | สอบถาม | ||
MXSU | – | 3141 | 240-400 | 17.8 -24.6 | mm. | 25.7 -32.6 | mm. | 33 – 47 | mm. | สอบถาม | ||
MXSU | – | 3151 | 500 | 25.5 -27.6 | mm. | 33.8 – 37.2 | mm. | 44 – 50 | mm. | สอบถาม | ||
MXSU | – | 3161 | 630 | 29.0 – 32.5 | mm. | 37.5 – 40.0 | mm. | 47 – 54 | mm. | สอบถาม | ||
MXSU | – | 3171 | 800 | 32.0 – 33.8 | mm. | 39.2 – 42.6 | mm. | 52 -57 | mm. | สอบถาม | ||
MXSU | – | 3181 | 1000 | 38.5 – 39.2 | mm. | 45.0 – 47.6 | mm. | 59 – 64 | mm. | สอบถาม | ||
MXSU | – | 5101 | 10-35 | 3.7 – 7.5 | mm. | 15.0 – 22.0 | mm. | 17 – 33 | mm. | สอบถาม | ||
MXSU | – | 5111 | 25-95 | 5.2 – 12.0 | mm. | 17.9 – 26.0 | mm. | 25 – 38 | mm. | สอบถาม | ||
MXSU | – | 5121 | 50-150 | 7.2 – 15.0 | mm. | 20.2 – 29.5 | mm. | 28 – 38 | mm. | สอบถาม | ||
MXSU | – | 5131 | 95-240 | 10.3 – 19.2 | mm. | 23.0 – 33.6 | mm. | 30 – 43 | mm. | สอบถาม | ||
MXSU | – | 5132 | 150-300 | 12.9 – 21.6 | mm. | 25.0 – 35.5 | mm. | 33 – 48 | mm. | สอบถาม | ||
MXSU | – | 5141 | 240-400 | 17.8 – 24.6 | mm. | 29.9 – 38.8 | mm. | 35 – 49 | mm. | สอบถาม | ||
MXSU | – | 5151 | 500 | 25.5 – 27.6 | mm. | 37.2 – 41.6 | mm. | 48 – 54 | mm. | สอบถาม | ||
MXSU | 5161 | 630 | 29.0 – 32.5 | mm. | 39.2 – 44.7 | mm. | 50 – 58 | mm. | สอบถาม | |||
MXSU | – | 5171 | 800 | 32.0 – 33.8 | mm. | 44.8 – 46.9 | mm. | 58 – 61 | mm. | สอบถาม | ||
MXSU | – | 5181 | 1000 | 38.5 – 39.2 | mm. | 49.4 – 53.2 | mm. | 64 – 67 | mm. | สอบถาม | ||
MXSU | – | 6111 | 35-95 | 6.0 – 12.0 | mm. | 24.0 – 30.0 | mm. | 34 – 43 | mm. | ฿ 24,000 | ||
MXSU | – | 6121 | 70-150 | 8.7 – 15.0 | mm. | 26.2 – 34.5 | mm. | 34 – 44 | mm. | ฿ 28,000 | ||
MXSU | – | 6131 | 150-300 | 13.9 – 21.6 | mm. | 31.1 – 39.6 | mm. | 38 – 53 | mm. | ฿ 32,000 | ||
MXSU | – | 6141 | 240-400 | 17.8 – 24.6 | mm. | 36.2 – 42.8 | mm. | 40 – 54 | mm. | ฿ 34,000 | ||
MXSU | – | 6151 | 500 | 25.5 – 29.2 | mm. | 40.1 – 46.6 | mm. | 52 – 60 | mm. | ฿ 36,000 | ||
MXSU | – | 6161 | 630 | 29.0 – 32.5 | mm. | 45.8 – 50.5 | mm. | 55 – 68 | mm. | ฿ 40,000 | ||
MXSU | – | 6171 | 800 | 32.0 – 33.8 | mm. | 50.1 – 53.4 | mm. | 62 -66 | mm. | สอบถาม | ||
MXSU | – | 6181 | 1000 | 38.5 – 39.2 | mm. | 55.7 – 58.5 | mm. | 69 -73 | mm. | สอบถาม |
Inline joint for 3-core polymeric cables with wire shield, without armour
Kit Number | 12kV | 24kV | 36kV | Diameter | Diameter over | Diameter Cable | Price | |||||
Conductor | Core Insulation | Oversheath | Baht/1core kit | |||||||||
MXSU | – | 3311 | 35-95 | 6-12 | mm. | 14.0 -21.8 | mm. | 42.5 -61 | mm. | สอบถาม | ||
MXSU | – | 3321 | 70-150 | 8.7 – 15.0 | mm. | 17.6 – 24.3 | mm. | 45 – 68 | mm. | สอบถาม | ||
MXSU | – | 3331 | 95-240 | 10.3 – 19.2 | mm. | 18.5 – 29.4 | mm. | 53 – 77 | mm. | สอบถาม | ||
MXSU | – | 3332 | 150-300 | 12.9 – 21.6 | mm. | 21.6 – 31.4 | mm. | 59 – 85 | mm. | สอบถาม | ||
MXSU | – | 5311 | 35-95 | 6-12 | mm. | 18.5 – 26.0 | mm. | 52.5-71.5 | mm. | สอบถาม | ||
MXSU | – | 5321 | 50-150 | 7.2 – 15.0 | mm. | 20.2 – 29.5 | mm. | 55 – 80 | mm. | สอบถาม | ||
MXSU | – | 5331 | 95-240 | 10.3 – 19.2 | mm. | 23.0 – 33.6 | mm. | 62.5 – 89 | mm. | สอบถาม | ||
MXSU | – | 5332 | 150-300 | 12.9 -21.6 | mm. | 25.0 – 35.5 | mm. | 70 – 96 | mm. | สอบถาม |
CENELEC HD 629.1 S1 | Raychem Joints MXSU passed all tests for XLPE insulated cables according to CENELEC HD 629.1 S1 | |||||||||||
IEC 60502-4 | or IEC 60502-4 including impact tests at ambient and at low temperature. | |||||||||||
Additional tests reflecting | Raychem joints MXSU were subjected to additional tests which are not part of any European standard | |||||||||||
future network operation | but reflect future demands in modern network operator Overload operation of cables : More than 800 | |||||||||||
hours of electrical heat cycling at conductor temperature of 130 °C with a volatge of 2.5 times the | ||||||||||||
operating voltages Uo | ||||||||||||
Oversheath testing as the routine test method of cable networks: Voltage withstand tests between the | ||||||||||||
screen wires and the water bath for 15 minutes at 15 kV at 8 kV AC. | ||||||||||||
IEC 61238-1 class A | Mechanical connectors used in raychem joints MXSU, pass the requirements in accordance with | |||||||||||
IEC 61238-1 class A |